Zixi Broadcaster/ZEC v18 Docum...
...
ZEC Outputs
ZEC Network Bonding

ZEC Broadcaster Output with Network Bonding

1min

A ZEC can push a stream to a Zixi Broadcaster that has been divided into multiple network channels by utilizing multiple NICs. The Zixi Broadcaster at the destination will subsequently reuniting them into a single input stream.

To add network bonding to a Push Output:

1

Create a Push Output, by following the instructions in the ZEC Adding Push Outputs section.

2

In the Output Parameters section, select the Bond Links checkbox.

Document image

3

In the Links section, click the + button to add a second link.

4

In the Host field, type the IP address of the destination Zixi Broadcaster.

5

In the Port field, type the destination port number of the Zixi Broadcaster to which you want to stream. Default: 2088

6

In the Local IP field, select the NIC in the ZEC (source) that you want to use to stream.

7

Configure additional parameters as required

8

Click OK to save the ZEC Out