Zixi Redundancy
Dual NIC Redundancy
Dual NIC PUSH Redundancy (Hot Redundancy)
5min
this topology includes two simultaneous streams delivered in parallel from a single source using two nics to a single target in a hot redundancy configuration if the latency of the outputs is identical, the streams will be frame synced, provided that the video is synced on entry source configuration the following procedure describes how to configure a zixi feeder to push a redundant stream to a target host in a hot redundancy configuration in order to configure a hot redundancy you will need to create two outputs in zixi feeder, each output will use a different nic each nic has a separate ip address the procedure does not cover instructions on how to configure the input into the zixi feeder to configure the first output in the source node (e g zixi feeder) on the outputs page of zixi feeder, click the new output button, located in the upper right end corner of the screen in the name field, type a new name for the output in the type field select push to broadcaster in the input name field select the relevant the input stream in the program field, if you have created a filter for the stream, select the relevant program in the stream id field, enter a stream id (alphanumeric) the same stream id will be also configured in the target node (push input) optional in the password field, specify a string to be used at the destination to authenticate that the pushing broadcaster is allowed to push this stream in the max bitrate field, specify the maximum bitrate of the stream default 8000 this is used for internal memory allocation and will not affect the transmitted bitrate recommended double the bitrate of the stream in the max latency field, specify the buffer size that zixi broadcaster will keep for error correction for example, 6000 milliseconds would ensure that the stream is protected for six seconds of errors in the network default 6000 in the host field, enter the host name or ip of the primary target in the port field, specify the destination port to listen on for the push stream (default 2088) in the ip field, select from the drop down menu, the ip address of the nic (network interface card) in the source through which the stream will be pushed click ok the output is added to the outputs list to configure the second output in the source node (e g zixi feeder) repeat the steps above to configure the second output, however in the ip field, select from the drop down menu, the ip address of the secondary nic in the source through which the stream will be pushed the stream in the second nic should have the same stream id as the first output target configuration the following procedures describe how to configure the target zixi broadcaster in a hot redundancy configuration the target should include two inputs that use the same stream ids, as configured in the first and second outputs in the source to configure the first target input (e g zixi broadcaster) click the inputs tab at the top of the primary zixi broadcaster administrative screen click new input on the upper right hand side of the screen select the push option create an input at the primary target, ensuring the “stream id” matches that of the first source output configure additional parameters as required click ok to configure the second target input (e g zixi broadcaster) click the inputs tab at the top of the secondary zixi broadcaster administrative screen click new input on the upper right hand side of the screen select the push option create an input at the secondary target, ensuring the “stream id” matches that of the first and second source output configure additional parameters as required click ok cost considerations the configuration also requires using double the up link bandwidth allocation of twice the expected maximum bit rate with head room is advised latency considerations for detailed recovery time details, please contact your zixi representative